How do you configure the stack configuration file?
KB#69 - SS7,Firmware
For full details of the parameters configurable via the SS7 stack please consult the "SS7 installation and administration guide".
A few common configuration examples follow:
Connection to one DPC
[SP]
LocalPC=1
[ISUP]
[EndISUP]
[MTP3]
[DESTINATION]
RemotePC=2
[EndDESTINATION]
[EndMTP3]
[EndSP]
Corresponding firmware configuration:
Port 0: -cOPC1 -cDPC2 -cTS16 -cSLC0 -cCIC1,fffffffe,fffefffe
Loopback configuration
[SP]
LocalPC=1
[ISUP]
[EndISUP]
[MTP3]
[DESTINATION]
RemotePC=2
[EndDESTINATION]
[EndMTP3]
[EndSP]
[SP]
LocalPC=2
[ISUP]
[EndISUP]
[MTP3]
[DESTINATION]
RemotePC=1
[EndDESTINATION]
[EndMTP3]
[EndSP]
Corresponding firmware configuration:
Port 0: -cOPC1 -cDPC2 -cTS16 -cSLC0 -cCIC1,fffffffe,fffefffe
Port 1: -cOPC2 -cDPC1 -cTS16 -cSLC0 -cCIC1,fffffffe,fffefffe
Using STPs
[SP]
LocalPC=1
[ISUP]
[DESTINATION]
RemotePC=2
[EndDESTINATION]
[MTP3]
[STP]
AdjacentPC=3
[EndSTP]
[STP]
AdjacentPC=4
[EndSTP]
[DESTINATION]
RemotePC=2
[ROUTE]
AdjacentPC=3
[EndROUTE]
[ROUTE]
AdjacentPC=4
[EndROUTE]
[EndDESTINATION]
[EndMTP3]
[EndSP]
Corresponding firmware configuration:
Port 0: -cOPC1 -cDPC3 -cTS1 -cSLC0 -cOPC1 -cDPC4 -cTS2 -cSLC0 -cOPC1 -cDPC2 -cCIC1,fffffffe,fffefff8